How much heat is lost through windows: what a camera shows

Guides November 1, 2026 13 min read

A thermal image of a window looks like a verdict. The pane glows orange against a calm blue wall and seems to say: this is where the money goes. People reach for a camera when they want to know how much heat is lost through windows, and the picture appears to answer. On its own, it often answers a different question.

A thermal camera reads the temperature of surfaces and paints it in colour. It does not measure heat flow, it cannot see through glass, and it cannot tell you how well a window is rated. Its strength is around the window rather than in the middle of it: the joint between frame and wall, the reveal, the sill, the head of the opening, and the seals and meeting rails where air finds a way through. Aim it at the centre of the pane and much of what you see is reflection.

In practice, the camera is most useful along the frame edges and reveals, not on the glass. Suspected air leaks are easier to confirm with the simple checks in our guide to draughty windows. If the frames themselves are past saving, describe the openings on the contact page.

The expensive misreading: a bright pane is not a hole

Picture the screen on a frosty evening. The glass is a slab of hot orange. The brickwork beside it is an even, reassuring blue. It is hard to look at that and not start pricing new windows.

Three things tend to go wrong from there.

The common thread is reading a picture of temperature as a picture of loss. They are related. They are not the same thing.

Why glass fools the camera

Most building cameras work in the long-wave part of the spectrum, and ordinary window glass does not let that radiation through. So the camera reads the surface of the pane plus whatever the pane is reflecting. For a thermal camera, glass behaves rather like a dark mirror.

Indoors, stand square to a window and the warm blob in the middle may well be you. There is a quick test. Move. A hot spot that slides across the pane as you walk is a reflection. One that stays put belongs to the surface.

Outdoors, the mirror shows other things. A clear night sky reads extremely cold, so glass facing it can look icy and perfect. Turn slightly and the same pane picks up a neighbour's warm wall, a street lamp or a parked car that has just been driven. None of that is your window.

A few other limits are worth knowing before you draw conclusions:

Where the camera is worth using: the frame perimeter

Now turn the camera away from the glass and follow the line where the window meets the house. On site it rarely looks as dramatic as the glowing pane, yet this is where the useful information sits.

The joint between frame and wall

Seen from inside on a cold night, a thin cold line tracing the edge of the frame onto the plaster suggests that the gap between frame and wall is poorly filled, or that air is moving through it. Lift off a loose reveal lining over a line like that and you may find a few brittle crumbs of old foam and a lot of empty space behind them.

When that joint is redone, it helps to know what each part does. Foam, insulation and sealing tapes fill, insulate and seal the gap. They do not hold the frame in place; mechanical fixings into the wall do that. Our article on what happens on site during timber window installation covers the sequence.

Reveals, sill board and the head of the opening

A cold patch spreading from the top corners, or along the whole head of the opening, often points at the lintel rather than the window. Concrete and steel lintels carry heat out of the room more readily than the wall around them. The same applies to a cold sill board, or a reveal where the wall insulation stops short of the frame. These are thermal bridges in the building, and new windows will not cure them. A cold corner of that kind is also a likely place for mould to start, so it deserves attention whatever happens to the window itself.

Seals, meeting rails and bottom rails

Air leaks show up on camera as cold "tongues" that spread from a joint onto the frame or the wall below it. On a sliding sash they tend to appear at the meeting rail and along the sides of the sashes. On a casement, the bottom rail and the corners on the handle side are the places to look, especially where a sash has dropped on its hinges. Where adjustment is possible, it should follow the instructions of the hardware or seal manufacturer for that system; not every window has the same options.

The camera narrows down where to look. Confirming a draught is easier with the back of your hand and a strip of paper, and the draughty windows guide walks through those checks without repeating them here.

Trickle vents

A neat cold rectangle at the head of the frame is very often a trickle vent. It is supposed to let air in. Do not seal it to tidy up the image; check that it opens and closes as it should.

What you see on screen What it can mean Why the reading can mislead Sensible next step
Warm patch in the middle of the glass Reflection of you, a lamp or a radiator Glass reflects long-wave heat like a mirror Move and re-shoot; ignore if the spot follows you
Cooler band round the glass edge, darker corners Normal edge effect of a sealed unit Looks like a failed seal to an untrained eye Compare with other windows on the same colour scale
Thin cold line where frame meets plaster Poorly filled installation joint or air leak A cold wall surface alone does not prove air movement Check with hand and paper; inspect behind the lining
Cold tongue spreading from a sash joint Worn seal, dropped sash or gap at the meeting rail Grows or shrinks with wind and fans Repeat with extract fans on, unless an open-flued appliance is in use; adjust per manufacturer instructions
Cold area across the head or top corners Lintel or wall thermal bridge Blamed on the window by default Treat as a building issue; watch for mould
Cold rectangle at the top of the frame Trickle vent Looks like a defect Leave open; it is there for ventilation

If a scan leads you back to frames that are rotten, split or warped beyond adjustment, our timber window range shows how the joinery, glazing and seals are put together.

Setting up a scan that tells you something

A thermal camera needs a strong, steady difference between inside and outside before its pictures mean much. A mild, sunny afternoon gives you a pretty image and almost no information.

One setting deserves its own warning. Most cameras rescale the colours automatically to whatever is in the frame. Point one at a window where the warmest and coldest surfaces are close together and a small difference is stretched across the whole palette, so a slightly cooler sash corner turns a deep, bruised purple. Lock the temperature range, or compare images taken on the same scale, before deciding that one window is worse than another.

Meeting rail of a painted timber sliding sash window with brass catch
Meeting rails and sash edges are where air leaks tend to show as cold tongues on a thermal image.

So how much heat is lost through windows?

It depends on the house, and a camera cannot put a figure on it. Heat leaves through a window in two main ways, and there is a third effect you feel rather than measure. The camera cannot put a number on any of them.

Energy assessors estimate a window's share of a home's heat loss from rated values, measured areas and the rest of the building fabric, not from photographs. Published percentages vary widely because houses vary widely: a cottage with small openings and a 1970s house with walls of glass are not the same problem. Treat any single figure for "the share lost through windows" with suspicion, and do not try to read one off a colour palette.

A thermal camera is a good witness and a poor judge.

When the picture points away from the windows

A good share of what a camera finds near a window is not the window's fault, and the fix is often cheaper than replacement.

A sound double-glazed window with a cool edge band is doing what its construction allows. Sealed glass units show that band, including the units in the timber windows we make; point a camera at one of them on a cold night and you would see it too. Replacing a window like that because of a picture spends money that would usually buy more comfort elsewhere: insulating the reveals, re-filling the installation joint, sealing genuine draughts, fitting heavier curtains, or tackling the loft.

Old single glazing is different. The glass will read cold, because it is. Even then, repair and draught-sealing tend to come first, and the camera is better at telling you which frames are leaking than whether the whole set needs to go.

Replacement starts to make sense when the camera and your own checks point at the frames themselves: joints that have opened, sashes that no longer meet their seals after adjustment, timber that has gone soft and dark along the bottom rail.

Before you act on a thermal image

If most answers are yes, the image is worth acting on. If not, take it again.

Questions people ask about thermal images of windows

Does a thermal camera see through window glass?

No. Ordinary window glass blocks the long-wave radiation building cameras use, so the camera reads the surface of the pane and anything reflected in it. Rooms behind a window, and the gas inside a sealed unit, stay hidden.

Why does the edge of my glass look colder than the centre on the image?

Because it usually is a little colder, and that is normal. The spacer at the edge of a sealed unit conducts more heat than the gas-filled centre, and corners lose heat from more sides. Warm-edge spacers reduce the effect without removing it.

Is it better to scan windows from inside the house or from the street?

Inside, in most cases. From indoors you see the surfaces your room loses heat to, without the cold night sky reflected in the glass. Outside shots can still help with walls and joints, but only on a dry night with no sun on the facade for several hours.

Can a thermal image show whether the gas has leaked out of double glazing?

Not reliably. The camera reads the outer surfaces of the glass, and a change in the gas fill makes only a small difference to those surfaces, easily swamped by reflections and the colour scale. Misting between the panes is a clearer sign that a unit's seal has failed.

What did your image actually show: a bright pane, a cold line down the reveal, or a draught at the meeting rail? If it keeps pointing at frames that no longer close properly, describe the windows, their sizes and what the camera picked up on our contact page, and we can talk through the options for those openings.

Prepared by the Windows Latvia technical team

condensation draughts heat loss thermal imaging window frames
Share:

Need Expert Advice?

Our team can help you choose the right windows for your project - from energy ratings to installation.

Get a Free Quote
Free Consultation

How would you like to connect?

Choose your preferred way to reach us. We will respond within a few hours.

Request Quote Quick Contact

Thank you!

Your inquiry has been sent. We will respond within one business day.

Error

Failed to send. Please try again or call us directly at +371 27 063 302.